HSD
D SENSORS (Free Field)
SPECIFICATIONS
|
Parameter
|
HSD-2
(R)
|
HSD-4
(R)
|
| Aeq
(m2) |
1
x 10 -1 |
1
x 10 -2 |
| Frequency
Response (3 dB pt) |
>45
MHz |
>150
MHz |
| Risetime
(Tr 10-90) |
<= 7.4 ns |
<= 2.3 ns |
| Maximum
Output |
5
kV |
5
kV |
| Output
Connector |
TCC
– 100 ohm* |
TCC
– 100 ohm* |
| Mass |
2.15
kg |
0.59
kg |
| Dimensions
(cm) |
|
|
|
L
|
62.5 |
44.7 |
|
W
|
28.5 |
8.9** |
|
H
|
20.6 |
6.9 |
|
t
|
0.3 |
0.16 |
*100-OHM Twinaxial
Connector (EG&G Data Sheet 1340)
**Connector width is greater than W on Model 4 (11.7 cm).