ACC-43 CABLE COMPENSATOR

SPECIFICATIONS

Connector

Any standard RF type
(e.g., N, GR, BNC, SMA)

Bandwidth from DC up to
maximum of 400 MHz (3dB)

Customer to specify upper bandwidth limit desired.

Risetime (with specified cable)

<1.0ns for 400MHz bandwidth

Cable Type and Length

Customer to specify

Attenuation

Depends upon cable type and length and upper bandwidth limit specified.  Will be adjusted to a convenient value
(e.g., 3, 6, 10, 12, 14, or 20dB)

Maximum Continuous Input Power

250 mW

Maximum Input Pulse Voltage

1000 Volts for 1 µsec

(Data and Specifications Subject to Change without Notice)