| SYSTEM
COMPONENTS |
ODT-6F
ODT-8F
ODR-6FM
ACU-14
ABC-15
FOC-5200
ABC-23A |
8
– Input FO Transmitter
Integrated Input FO Transmitter
FO Receiver Module
ODS/PVS Controller
3 – Station Battery Charger
200 meter length Duplex FO Cable
Battery Pack |
| FO
ANALOG DATA CHANNEL CHARACTERISTICS (ODT/ODR) |
| Input |
8
SMA, 50 ohm, Single-ended per ODT-6F
(1 Type-N, 50 ohm, Single-ended per ODT-8F) |
Protection
Bandpass (-3 dB)
Dynamic Range
Gain
Maximum Output |
500
V Peak, 0.5 watt
1 kHz to 150 MHz
36 dB (1 dB unipolar pulse compression to tangential noise)
-64 to +40 dB in 1 dB steps
1 VPP |
| REMOTE
CONTROL (ACU-14) |
|
Local
Control/Display
Remote Control
FO Transmitter Controls
No. of FO Transmitters Supported |
Keypad
entry with CRT status display
IEEE-488 compatible
Power On/Off
Input Selection 1 of 8 for ODT-6F
Integrator of ODT-8F
System Gain -64 to +40 dB in 1 dB steps
Calibration Generator
Probe Verification
255 maximum |
| FOC-5200
FO CABLE ASSEMBLY |
Control
Fiber
Analog Data Fiber
Connectors
Cable Construction
Length |
200
micron step-index
100 micron graded-index
Amphenol 906 Series
Loose Tube, duplex
200 meters |
| APS-23A
BATTERY PACK |
|
Capacity
Operational Time
Protection |
>2AH
at 12VDC (2.5AH typical)
>10 hrs. continuous operation
>30 days standby operation
Built in protection against deep discharge, shorted output
and overcharge |
| PHYSICAL
SIZE (cm) |
|
ODT-XV/APS-23A
ODR-6F Chassis
ACU-14
ABC-15
OPTIONS
PVS-SW |
15.9
H x 14.0 L x 11.5 W, 13.0 kg
13.3 H x 48.3 W (19 inch EIA rack mount)
22.2 H x 48.3 W (19 inch EIA rack mount)
17.8 H x 48.3 W (19 inch EIA rack mount)
Automated Probe Verification Software for ACU-14. Requires
HP3488 switch controller and HP1980B digitizing oscilloscope. |