FPD D-DOT SENSOR
The FPD (Flush Plate
Dipole) sensor is mounted in a conducting surface (ground plane,
aircraft wing, etc.) and used to measure the normal component
of the displacement current (dD/dt). It can also be used to measure
the time rate-of-change of surface charge density dqs
/dt. (Data Sheet 1117 describes special qs
sensors.) The FPD sensor is extremely useful in EMP or lightning
fields of high electric stress or where minimum perturbation is
required. A special version adapts to the wing tip of a C-130
aircraft used for in-flight lightning measurements. The sensor
is a passive device and requires no power.
Data Specification Sheet
|